10. CARE AND CLEANING

WARNING!
Refer to "Safety information"
chapter.
Notes on cleaning:
• Clean the front of the appliance with a
soft cloth with warm water and a clean-
ing agent.
• To clean metal surfaces, use a usual
cleaning agent.
• Clean the appliance interior after each
use. Then you can remove dirt more
easily and it does not burn on.
• Clean stubborn dirt with a special oven
cleaner.
• Clean all accessories after each use
and let them dry. Use a soft cloth with
warm water and a cleaning agent.
• If you have nonstick accessories, do
not clean them using aggressive
agents, sharp-edged objects or a dish-
washer. It can cause damage to the
nonstick coating.
10.1 Pyrolytic cleaning
Remove all accessories and re-
movable shelf supports.
Do not start the pyrolytic
cleaning if:
• You did not remove the shelf
• You did not fully close the oven
1.
Remove the worst dirt manually.
2.
Set the Pyrolytic cleaning function.
Refer to "Oven functions".
3.
When
set the necessary procedure:
– P1 – If the oven is not very dirty.
The procedure is 1:30 h long.
– P2 – If you cannot easily remove
the dirt. The procedure is 2:30 h
long.
After 2 seconds the procedure starts.
supports or telescopic shelf
runners (if supplied). In some
models, the display shows "C1"
when this error occurs.
door. In some models, the dis-
play shows "C3" when this error
occurs.
flashes, press
To change the default length of the
procedure (P1 or P2), press
the length of the pyrolytic procedure.
You can use the End function to delay
the start of the cleaning procedure.
When the oven is at its set tempera-
ture, the door locks. The display
shows the symbol
the heat indicator until the door un-
locks.
Cleaning reminder
To remind you that the pyrolytic cleaning
is necessary, PYR flashes in the display
for 10 seconds after each activation and
deactivation of the appliance.
10.2 Lamp
Before you change the lamp:
• Deactivate the appliance.
• Remove the fuses from the fuse box or
deactivate the circuit breaker.
or
to
Replacing the lamp at the cavity
ceiling:
1.
Turn the lamp glass cover counter-
clockwise to remove it.
ENGLISH
, and then press
and the bars of
During pyrolytic cleaning the lamp
is off.
The cleaning reminder goes
out:
• After the end of the Pyrolytic
cleaning function.
• If you press "
" and "
the same time while PYR flash-
es in the display.
WARNING!
There is a risk of electrical shock.
The lamp and the lamp glass cov-
er can be hot.
CAUTION!
Put a cloth on the bottom of the
interior of the appliance. It pre-
vents damage to the lamp glass
cover and the cavity.
Always use the same lamp type.