Detewe Protocol; A.5.3 Detewe Protocol - Bosch NurseCall Main Unit User Manual

Table of Contents

Advertisement

56
en |
Group
16
17
18
19
20
21
22
23
24
Change day / night
If the change day / night is activated, the NurseCall system transfers all alarms during night to
the group 24. During the day, all groups 00 - 24 can be used. When switching from day to
night or vice versa, the message "Day-Night" is sent to the activated pagers.
Priority alarms
The assistance and fire alarms are priority calls sent to all activated pagers.
Call repetition
If alarms or messages are not acknowledged after approximately 7 minutes, call repetitions
are also sent to the group 23.
A.5.3

DeTeWe protocol

Characteristics
Only alarms or messages arriving to the alarm buffer are transmitted, except "Relay Off". The
transmission is fully alpha-numeric. Acknowledgement messages are also transmitted.
Alarms are sent to the DeTeWe user number attributed to the transmitter.
The default group is 00.
Group
00
01
02
03
04
05
06
07
08
F.01U.252.699 | V1.1 | 2012.01
The x digit can be programmed. Section Specific parameter for POCSAG, page 30.
Data rate: 9600 Bauds
Transmission: asynchronous
11 bit-structure (1 start bit, 8 data bits with odd parity, 1 stop bit)
half-duplex mode.
User number
001x128
001x136
001x144
001x152
001x160
001x168
001x176
001x184
001x192
User number
x00
x01
x02
x03
x04
x05
x06
x07
x08
User Manual