Chapter 4
Signal Connections
AT-MIO/AI E Series User Manual
Mode 1 Output Timing
The following are the timing specifications for an output transfer in
Mode 1:
WR*
OBF*
INTR
ACK*
DATA
Name
Description
T1
WR* = 0 to INTR = 0
T2
WR* = 1 to Output
T3
WR* = 1 to OBF* = 0
T4
ACK* = 0 to OBF* = 1
T5
ACK* Pulse Width
T6
ACK* = 1 to INTR = 1
All timing values are in nanoseconds.
T3
T1
T2
Figure 4-39. Mode 1 Output Timing
4-56
T4
T6
T5
Minimum
Maximum
–
250
–
200
–
150
–
150
100
–
–
150
National Instruments Corporation