IR-PhotoNotes™

IR-PhotoNotes™ are photograph annotations that allow the user to capture and
add multiple visible images of various objects, text, or other information that is
related to the analysis and reporting of an infrared image. Examples of an
annotation include motor name plates, printed information or warning signs,
larger views of the environment or room, and related equipment. Up to three
images can be captured with the visible image that is stored with the infrared
image as part of IR-Fusion technology. These visible images are only available
in the .is2 file format and are stored in the file so you do not need to collate
multiple files at a later time.
To add IR-PhotoNotes:
1. With an image in the buffer, push  to open the EDIT IMAGE
menu.
2. Push / to highlight IR-PhotoNotes.
3. Push  to enter the Picture mode.
4. Focus Imager on the object and pull the primary trigger.
5. Push  to continue.
6. Push  save the picture with the image.

Voice Records

To add a voice (audio) record:
1. With an image in the buffer, push  to open the EDIT IMAGE
menu.
2. Push / to highlight Add Audio.
3. Push  to record up to 60 seconds of audio. The display updates to
show the recorded time.
4. Push  to pause the recorder.
5. Push  when done.
6. Push  to review the audio file or  to save the audio with
the image.