Fixing Unit; Composition - Konica Minolta CF5001 Service Manual

Hide thumbs Also See for CF5001:
Table of Contents

Advertisement

FIXING UNIT

12. FIXING UNIT

12.1 Composition

TH4
PS17
TH2
TS2
PS16
M29
Symbol
[1]
Fixing roller /U
[2]
Fixing roller /L
[3]
Cleaning roller
[4]
Cleaning web
M29
Fixing motor
M54
Web motor
PS16
Fixing pressure release sensor
PS17
Fixing paper exit sensor
[2]
L4
L3
L2
Name
Toner fixing by means of pressure and heating
Heating roller method
Silicon rubber + PFA resin layers
Temperature: 210 °C
Toner fixing by means of pressure and heating
Heating roller method (driven by the fixing roller /U)
Pressure/release by means of cam drive
Silicon rubber + PFA resin layers
Temperature: 190 °C
Cleaning of the fixing roller /U
Cleaning of the cleaning roller
Driving of the fixing roller /U
Fixing roller /L pressure/release drive
24V brushless DC motor
Driving of the cleaning web, Synchronous motor
Fixing roller /L pressure/release HP detection
Paper exit detection from fixing
[1]
TH3
TH1
[3]
[4]
M54
TS1
Function or method
2-60
CF5001 Ver.1.0 Sep. 2003
FHCB
ACDB
CLOCK
F/R
LOCK
H/L
CVDB
8050ma2043e