B Tighten the screw on the double-sided collector
clamp using the size 5 Allen key.
i
USER NOTE
When the screw is tightened, the plastic
lugs at the pre-determined cut-off points
break away.
The grip (Fig. 48, Item 1) on the collector clamp now
grips the lower collector edges.
Repeat the procedure for all the other collectors.
Fitting the single-sided collector clamp on the left
Once all collectors are fitted, the two remaining single-
sided collector clamps can be attached.
B Push single-sided collector clamp (Fig. 49, Item 1)
into upper and lower profile rails.
B Push collector clamp up against the collector frame
and screw in place using size 5 Allen key (Fig. 49,
Item 2).
i
USER NOTE
When the screw is tightened, the plastic
lugs at the pre-determined cut-off points
break away and can be discarded.
6 720 613 055 (2006/04)
Fig. 48 Double-sided collector clamp between two collectors
1
Fig. 49 single-sided collector clamp (left)