Determining Space Required On Roof - Worcester FKT Series Installation Instructions Manual

Flat panel solar collectors, roof mounting for worcester solar heating systems
Table of Contents

Advertisement

Before installation
4.6

Determining space required on roof

Please note the following minimum space requirements.
Dimension A and B
Area required for the collector array.
Dimension C
At least two tiles to the roof or chimney. Otherwise there
is a risk of damaging the tiles, particularly if the tiles are
laid in mortar.
Dimension D
Roof overhang including gable wall thickness.
Dimension E
Minimum 30 cm for fitting the connection cables in
the attic.
Dimension F
Minimum 40 cm for installing the connection cables in
the attic (if installing a vent, sufficient space must also be
allowed for in the vicinity of the flow outlet).
Please note that the air vent must be the highest point of
the system.
Dimension G
Minimum 50 cm left and right of the collector array for
the pipework under the roof.
Dimension H
Dimension H is 1.900 mm (1.000 mm for landscape col-
lectors) and is the minimum distance from the upper
edge of the collector to the lower profile rail, which is in-
stalled first.
Space requirements for portrait collectors:
Number of collectors
2
3
4
5
6
7
8
9
10
Tab. 3
Space requirement for portrait collectors
14
Dimension A
Dim. B
2.32 m
2.07 m
3.49 m
2.07 m
4.66 m
2.07 m
5.83 m
2.07 m
7.06 m
2.07 m
8.17 m
2.07 m
9.34 m
2.07 m
10.51 m
2.07 m
11.68 m
2.07 m
H
Fig. 7
Clearances to be observed
Space requirements for landscape collectors:
Number of collectors
2
3
4
5
6
7
8
9
10
Tab. 4
Space requirement for landscape collectors
G
63043965.09-1.SD
63043965.09-1.SD
Dimension A
Dim. B
4.17 m
1.15 m
6.26 m
1.15 m
8.36 m
1.15 m
10.45 m
1.15 m
12.55 m
1.15 m
14.64 m
1.15 m
16.74 m
1.15 m
18.61 m
1.15 m
20.93 m
1.15 m
6 720 613 055 (2006/04)