Collector installation
Fitting corrugated pipe connectors to the first
collector
B Remove the rubber caps from the connections.
B Push corrugated pipe connectors (Fig. 45, Item 1)
onto the left-hand connections on the first collector.
B Push bracket (Fig. 45, Item 2) over the corrugated
pipe connector and collector connection to secure
the connection.
Putting the second collector in place
B Place the second collector onto the profile rails and
allow it to slide into the anti-slip protectors.
SYSTEM DAMAGE
through damaged corrugated pipe con-
nectors.
CAUTION!
B Do not use any tools, e.g. pliers
(Fig. 46, Item 2). These could render
the corrugated pipe connector unus-
able.
B Push the second collector on to the first in such a way
that the collector connections are pushed into the
preassembled corrugated pipe connectors (Fig. 46,
Item 1) on the first collector.
B Place second bracket (Fig. 46, Item 3) over the cor-
rugated pipe connector and collector connection.
SYSTEM DAMAGE
through unsecured corrugated pipe con-
nectors and end caps.
CAUTION!
B Secure each end cap with one bracket
and each corrugated pipe connector
with two brackets (Fig. 47, Item 1).