B Open the condensate trap cover.
Fig. 71
B Check and clean the condensate trap with clean
water.
B Screw the condensate trap cover back on.
10.3.2 FILLING THE CONDENSATE TRAP AFTER THE
MAINTENANCE WORKS
After the condensate trap maintenance, it's necessary to
fill it with water.
Proceed as follow;
B Remove the clip and disconnect the drain tube (
72).
Fig. 72
6 720 646 322 (2012/05)
6720680174-05. 1 Av
Fig.
6720801916-05.1V
B Fill the condensate trap by pouring approx. 400ml of
water into the top of the drain tube. To avoid damage
to the appliance use a funnel in this operation (
73).
6720646322-28.1V
Fig. 73 Filling the condensate trap after installation.
B Loosen the three screws of the control unit (
66).
B Put the control unit in service position by engaging its
tabs with the holes in the bottom horizontal sheet
metal (
Fig. 74).