APPLIANCE INFORMATION

3.10 TECHNICAL DATA

Technical characteristics
Power and flow
Nominal output
Minimum output
Output (adjustment range)
Nominal input
Minimum input
Gas data
Supply pressure
Natural gas
LPG (propane)
Gas consumption
Natural gas (Hi = 9,5 kWh/m3)
LPG (propane) (Hi = 12,8 kWh/kg)
Water data
Maximum permissible pressure
Minimum operating pressure
Minimum activation flow
Maximum water flow with temperature rise of 35°C
Minimum water pressure for maximum water flow
Combustion products
Flue gas flow
Natural gas
LPG - Propane
Temperature of combustion gases
Flue gas temperature at maximum output
Flue gas temperature at minimum output
General Data
Efficiency at nominal input
Voltage
Frequency
Maximum electrical power consumption
Type of protection
Ambient temperature permited
NET efficiency
Weight (excluding packaging)
Tab. 4
10
Symbol
Units
Pn
kW
Pmin
kW
Qn
kW
Qmin
kW
G20
mbar
G31
mbar
3
G20
m
/h
G31
kg/h
pw
bar
pwmin
bar
l/min
l/min
bar
kg/h
kg/h
°C
°C
%
V
Hz
W
IP
°C
%
kg
6 720 646 322 (2012/05)
CWi47
50.3
6
6 - 50.3
48.4
6
20
37
5.09
3.8
12
0.3
1.9
20.6
2.5
81.8
79.3
60 - 70
29
104
230
50
116
X4D
0 - 50
104
34