9.5
APPLIANCE CASCADING MODE
SETTING
Perform this procedure on all appliances in
the cascading set up.
All appliances in the installation must be
adjusted to the same outlet water
temperature. By selecting on any appliance
all the others will update the set
temperature accordingly.
B Push ON/OFF switch to the OFF position.
B Press and hold the program button
press the ON/OFF button to the ON position. As soon
as '188' flashes on the display, release the
button.
– The display should now read P2.
B Press the
button until P5 appears.
+
B Press Program button
– The display should now read NC (normal mode).
B Press
button until CC (cascading mode) appears.
+
B Press and hold Program button
on the display.
B To enter in the main menu, press
– After the "CC" is selected, two new menus will
become available in the main menu, PH and PC.
To acess PH and PC menu,
B Press the
button until PH or PC appears.
+
PC - PRIMARY AND SECONDARY SELECTION
• CM - Primary
– Only one appliance in the cascading system should
be selected as "Primary".
• CS - Secondary (default)
– The others appliances in the cascading system
must be "Secondary".
PH - CASCADING MODE SELECTION
• IC - Intelligent Cascading (default)
– The primary will rotate after 100h/work.
• SC - Simple Cascading
– There will not be any primary rotation when this
appliance is selected as primary.
Selection is done pressing the button
until the display starts flashing.
The appliance is now programmed to operate in the
cascading mode.
6 720 646 322 (2012/05)
and then
.
until CC blinks
button.