COMMISSIONING
9.4

PROGRAM VALUES

This section describes details on programming the
appliance. For most applications the factory default
values will provide robust and stable operation.
Program
Description
P1
Maximum Power
P2
Minimum Power
P3
Remote
Controls
installed
P4
Access to
Diagnostic Mode
P5
Cascade Mode
P6
Temperature Unit
P7
Appliance Type
P8
Back light
P9
Fan Purge
PH
Cascading type
PC
Master/Slave
mode
Tab. 20
40
Factory default
Min
N. Gas: 45
21
Propane: 42
12
12
_0
_0
E
0d
NO
NO
ºC
ºF
Cd
Cd
(Condensing)
(Condensing)
dE
dE
IC (Intelligent
IC (Intelligent
Cascade)
cascade)
CS
CS
CAUTION: Misadjusted program values can
lead to appliance malfunction, errors, and
service calls.
Max
Comment
N. Gas: 45
See chapter 9.2.
Propane: 42
Note: reducing P1 values
below maximum will
reduce maximum power of
the appliance.
20
See chapter 9.2.
6
See chapter 9.8.
10f
See chapter 9.6.
CC
To activate the cascade
mode it's necessary to
install the "kit cascade"
(part number 7 736 500
272)
ºC
See chapter 9.6.
nC
Condensing /
Non-condensing
Note: incorrect setting will
cause errors.
ON
dE : turns back light off
after 60 seconds from last
button pushed.
ON: turns backlight on
permanently.
Runs secondary fan and
primary fan when P9 is
selected by depressing the
"P" - button
SC (Simple
cascade)
This menu is only available
when cascade mode
(Program P5) is selected
CM
CC.