INSTALLATION INSTRUCTIONS

6.11 FILLING THE CONDENSATE TRAP

CAUTION:
Before the first start up of the appliance,
after a long period of inactivity or whenever
it follows the cleaning of the condensate
trap;
B Fill the condensate trap with water, to
prevent flue gases entering the room
where the appliance is installed in.
The condensate trap can be filled before or
after connecting the flue gas pipe.
6.11.1 FILLING THE CONDENSATE TRAP BEFORE
FLUE GAS PIPE INSTALLATION
B Fill the condensate trap by pouring approximately
400ml of water into the flue gas connector on the top
of the appliance (
Fig. 45).
Fig. 45 Filling the condensate trap at start up
6.11.2 FILLING THE CONDENSATE TRAP AFTER FLUE
GAS PIPE INSTALLATION
Please proceed as follows;
B Remove front cover (
B Open the four clips and remove the combustion
cover.
30
400ml
6720646322-22.1V
Fig. 25).
B Remove the clip and disconnect the drain pipe (
46).
Fig. 46
B Fill the condensate trap by pouring approximately
400ml of water into the top of the drain pipe. To avoid
damage to the appliance use a funnel (
6720608917-07.1AL
Fig. 47 Filling the condensate trap after installation
After appliance has been out of use for a
long time or after cleaning the siphon, refill
the condensate trap with water.
6 720 646 322 (2012/05)
Fig.
6720608948-05.1AL
Fig. 47).