2.
Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the
maximum power that the processor can dissipate. TDP is measured at maximum T
3.
These specifications are based on final silicon characterization.
4.
Power specifications are defined at all VIDs found in
multiple VIDs for each frequency.
5.
FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor
frequency requirements.
Figure 5-23. Tcase: 4-Core 95W Thermal Profile 1U
1.
Please refer to
2.
Implementation of this Thermal Profile should result in virtually no TCC activation. Refer to the Intel®
Xeon® Processor E5-1600/E5-2600/E5-4600 Product Families Thermal/Mechanical Design Guide for
system and environmental implementation details.
Figure 5-24. DTS: 4-Core 95W Thermal Profile 1U
128
Table 5-23
for discrete points that constitute the thermal profile.
Intel® Xeon® Processor E5-1600/E5-2600/E5-4600 Product Families
Thermal Management Specifications
Table
7-3. The processor may be delivered under
.
CASE
Datasheet Volume One