Section 5: Door Control Module - Max3; Introduction; Standalone; On-Line - Honeywell Galaxy 3-48C Installation Manual

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

Galaxy 3 Series Installation Manual
Section 5: Door Control Module - MAX

Introduction

3
The MAX
is a proximity reader access control device for a single door, which can also be used for setting
and unsetting of your alarm control panel. The MAX

Standalone

In this configuration the MAX
connecting the internal relay output to a door lock, external relay or into the keyswitch zone of the alarm
system. When in standalone mode the MAX
or tags.The proximity cards and tags each have unique ID numbers and must be identified to the MAX
before being used to operate the system. The MAX
least three reserved for Masters. Once programmed, the ID number of the tags and cards are stored indefi-
3
nitely in the MAX
memory until voided (removed) or erased. Removing power from the MAX
erase the programming memory.
3
Note : The MAX
defaults to standalone mode. It can be configured to on-line mode directly from and of the
Galaxy 3 Series control panels.

On-line

3
The MAX
can operate in on-line mode, with the Galaxy 3 Series control panel range, as a completely inte-
grated module on the system. In this configuration the MAX
system set/unset control with complete user traceability stored within the Galaxy control panel.
For detailed instructions on how to programme the MAX
Series Programming Manual IP1-0033, Option 63.2=MAX.
Installing the MAX
3
MAX
Pack
3
Your Max
pack contains the following:
3
• Max
proximity reader *
3
• Max
drilling template
3
• Max
installation instructions
• Surge suppressor
3
* The MAX
is supplied with 3 metres of 12
wire E111235 AWG cable which is fixed and
sealed through a keyhole opening on the rear
3
surface of the MAX
3
can be used for either door control or alarm system set/unset control, by either
3
is programmed and operated using the MAX
3
.
3
can be configured in one of two ways:
3
memory can store up to 999 ID numbers, including at
3
can be used for both door control and alarm
3
onto the system in on-line mode refer to Galaxy 3
Mounting the MAX
To mount the MAX
diagrams provided with the drilling template.
The drilling template should be used as an aid
to locate the holes required to secure the
3
MAX
and insert the connection cable.
3
The MAX
comes with an infra red lid tamper.
The tamper is activated when the lid is re-
moved from the MAX
5-1
MAX
3
3
3
proximity cards
3
3
does not
3
3
use the step by step
3
unit.

Hide quick links: