Stand-By Battery; Battery Start-Up; On-Board Power Supply Unit - Honeywell Galaxy 3-48C Installation Manual

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

Galaxy 3 Series Installation Manual

Stand-by Battery

The Galaxy 3 Series control panels can accommodate up to 2 x 17 Ahr batteries. Ensure that the battery
connector leads on the control panel Powers Supply Unit (PSU) are connected to the correct terminals on the
battery.
CAUTION:
There is a risk of explosion if the battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.

Battery Start-up

The system can be powered up via the Battery Start-up jumper if there is no AC power. To do this, short
out the Battery Start-up jumper for the duration of the configuration process only. Never leave the Battery
Start-up connected or else deep discharge of the Stand-by Battery will occur.

On-Board Power Supply Unit

The on-board Power Supply Unit (PSU) supplies and monitors power to the system and peripherals. The
following table shows the fuse name and value in amps.
G3-144/G3-520: The Galaxy 3 Series control panel contains four fuses. Details are given in the table below.
NOTE: The G3-48 does not require fuse AUX2.
FUSE NAME
AUX1
AUX2
BATT
BELL
Power Monitoring Characteristics:
G3-48
The PSU total capacity is 1.5A. Internally the PSU
is split in two in order to ensure sufficient current is
always available for stand-by battery recharge.
The PSU capacity is broken down as follows:
Battery:
Control PCB:
AUX +12V:
The PSU is available for zones/outputs and peripherals.
C
o
n
r t
l o
P
B -
A
T
+
B
A
T
Table 2-3. Battery/Control Panel connections
VALUE (AMPS)
1.0
RS485 Line 1, RIO 0, Zones 1-8: +12V,
on-board comms
1.0
RS485 Line 2, RIO 1, zones 1-8 +12V
1.6
Battery
1.0
Outputs RIO 0 1-4, RIO 1 1-4, Horn output 20 mm, anti-surge
Table 2-4. On-board PSU Fuses
Low battery level: 11.2V
Deep discharge protection: 10.5V
Overvoltage protection: 14.7V
0.75A
0.25A
0.5A
Stand-by Battery
a
n
l e
B
t a
e t
y r
-
e v
t
r e
m
n i
l a
+
e v
t
r e
m
n i
l a
MONITORS
G3-144/520
The PSU total capacity is 2.5A. Internally the PSU is
split in two in order to ensure sufficient current is al-
ways available for stand-by battery recharge.
The PSU capacity is broken down as follows:
Battery:
Control PCB:
AUX +12V:
2-9
TYPE
20 mm, anti-surge
20 mm, anti-surge
20 mm, anti-surge
1.25A
0.25A
1.00A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Galaxy 3-144Galaxy 3-144cGalaxy 3-520cGalaxy 3-520