Creating A Splash Screen - Motorola MC3000R - Win CE 5.0 Core 312 MHz Integration Manual

Mc3000 series integration guide
Hide thumbs Also See for MC3000R - Win CE 5.0 Core 312 MHz:
Table of Contents

Advertisement

IPL Errors (Continued)
Table 4-6
Error Text
There is no more heap
space available
Insufficient data
available to complete
record
Invalid Symbol HEX file -23
Unrecognized or
unsupported HEX
record
Invalid data in HEX file
Exceeded max size
Partition is not valid on
this device
Wrong destination
code
File type does not
support IPL Auto
Select
Non-contiguous record
found
Timed Out - No data
Fail: Buffer Overrun
Partition Table not Valid -33
Invalid file format

Creating a Splash Screen

The source bitmap files used to create the default splash screens for the mobile computer are supplied with the
DCP for MC3000 These files can be modified using any of the standard windows image editors, allowing
customization for particular customers.
Error
Number
-14
There is no more heap space available for the download procedure. Restart
IPL and retry the download. If the failure persists, contact service with details
of what is being downloaded.
-21
A Symbol HEX file download was attempted but the HEX file is invalid.
Ensure the file is in Symbol HEX file format.
A Symbol HEX file download was attempted but the HEX file is invalid.
Ensure the file is in Symbol HEX file format.
-24
The Symbol HEX file being downloaded contains an invalid or unrecognized
HEX record. Ensure the file is in proper Symbol HEX file format.
-25
The Symbol HEX file being downloaded contains invalid data. Ensure the file
is in proper Symbol HEX file format with valid HEX data.
-26
The download file is too large to fit into the space allocated for it. Either make
the file smaller or increase the space allocated for it by altering the partition
table.
-27
The downloaded file specifies a partition entry that does not exist on the
device. Only download files that are valid for this device, or change the
partition table so that the new file is valid on the device.
-28
A specific partition was chosen from the IPL main menu (not Auto Select) but
the file selected for download was for another partition. Ensure that the
partition selected from the IPL main menu matches the file selected for
download.
-29
Monitor, Power Micro and Partition Table cannot be loaded with Auto Select.
Select the appropriate area, and try again.
-30
A Symbol HEX file download was attempted but the HEX file is invalid.
Ensure the file is in Symbol HEX file format.
-31
IPL was waiting for data from the source device but timed out before
receiving any. Check the source device connectivity and retry.
-32
The serial port device could not keep up with incoming data. Retry the serial
download with a lower baud rate.
The size of flash memory is different than that described in the partition table.
Retry the download with the correct partition table file.
-34
The file format is invalid. Only Symbol HEX files are supported by IPL.
Application Deployment for WinCE 5.0 4 - 21
Probable Cause

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mc3090gMc3090sMc3090r

Table of Contents