Ipl Error Detection - Motorola MC3000R - Win CE 5.0 Core 312 MHz Integration Manual

Mc3000 series integration guide
Hide thumbs Also See for MC3000R - Win CE 5.0 Core 312 MHz:
Table of Contents

Advertisement

TCM Error Messages (Continued)
Table 4-5
Error
Failure creating binary file
Hex File To load is missing or invalid
Could not locate mobile computer
name in TCM.ini file
Incorrect disk sizes in TCM.ini file
INVALID DIRECTORY
One of the disk sizes is one sector in
size
INVALID VOLUME NAME
Corrupt TCM.INI file! (Invalid value of
VolumeDivisor)
Invalid version of TCM script file
Corrupt or missing TCM.ini file
FAILED CONNECTION TO COM
PORT (Could not get status)
FAILED CONNECTION TO
TERMINAL (Terminal Not Connected
Properly/Terminal Not Ready to
Receive)

IPL Error Detection

While receiving data, IPL performs many checks on the data to ensure that the data is received correctly. If an error
is detected, IPL immediately aborts the download, and reports the error on an error screen.
Error screens may vary depending on the action being performed. A sample error screen may look like the screen
pictured below:
Application Deployment for WinCE 5.0 4 - 19
Description/Solution
TCM failed to open/create an intermediate binary file.
In Load Terminal window, the file selected to load has invalid status.
While loading the
Script Properties
section corresponding to the mobile computer type specified by the current
opening script. Either TCM.ini or the script file is invalid.
The total disk size specified in the script does not match the total disk size
defined in the corresponding TCM.ini section. Check if the script is corrupt
or the TCM.ini has changed after the script was created.
In
window, the selected System File Path is not a valid
Script Properties
directory.
In
window, one of the disks is too small (one sector in
Script Properties
size). This may cause problem while building images, especially when
cushion is enabled. Increase the disk size.
In Script Properties window, one of the volume labels is not valid.
The VolumeDivisor entry is missing or invalid in the TCM.ini. Reinstall TCM
or recover TCM.ini.
The TCM script was not created by this version of TCM.
TCM could not find TCM.ini file.
While downloading images to mobile computer, TCM failed to connect to
the selected COM port. Check if the COM port is free and is properly
configured.
While downloading images, TCM failed to connect to the mobile computer.
Check if the correct flow control protocol is selected and the mobile
computer is properly connected and is in a listening state.
window, TCM could not find the TCM.ini

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mc3090gMc3090sMc3090r