6-12
DSP Commands
34h
Output
34h
Remarks
For MIDI UART mode, a read from the DSP is taken as reading MIDI data and a
write to the DSP is taken as sending MIDI data.
To terminate MIDI UART mode, send a DSP reset command.
The DSP reset command behaves differently while the DSP is in MIDI UART mode.
It terminates MIDI UART mode and restores all DSP parameters to the states prior to
entering MIDI UART mode.
See Also
command 30h, Polling mode MIDI input
command 36h, UART polling mode MIDI I/O with time stamping
Available
1.xx
35h
Output
35h
Remarks
After sending this command, the DSP will generate an interrupt to signal the
application when there is any in-bound MIDI data.
Refer to command 34h on the characteristic of MIDI UART mode and on how to
terminate it.
See Also
command 31h, Interrupt mode MIDI input
command 37h, UART interrupt mode MIDI I/O with time stamping
Available
1.xx
UART polling mode MIDI I/O
2.00
2.01+
3.xx
UART interrupt mode MIDI I/O
2.00
2.01+
3.xx
4.xx
4.xx