to allow or not allow the password change. If there are network configuration settings that differ from the current
iDRAC settings, the user is prompted to either accept or reject the changes.
NOTE: If there is a LAN or IPMI over LAN difference, the user is prompted to accept the QuickDeploy IP
address setting. If the difference is the DHCP setting, the user is prompted to accept the DHCP QuickDeploy
setting.
To copy the QuickDeploy settings into the iDRAC Network Settings section, click Auto-Populate Using QuickDeploy
Settings. The QuickDeploy network configurations settings are copied into the corresponding fields in the iDRAC
Network Configuration Settings table.
NOTE: Changes made to QuickDeploy fields are immediate, but changes made to one or more iDRAC server
network configuration settings may require a couple of minutes to propagate from CMC to iDRAC. Clicking
Refresh early may display only partially correct data for one or more iDRAC servers.

Modifying iDRAC Network Settings for Individual Server iDRAC

Using this feature, you can configure the iDRAC network configurations settings for each installed server. The initial
values displayed for each of the fields are the current values read from the iDRAC. To use this feature, you must have an
Enterprise License.
To modify the iDRAC Network Settings:
1.
In the left pane, click Server Overview, and then click Setup . On the Deploy iDRAC page the iDRAC Network
Settings section lists the iDRAC IPv4 and IPv6 network configuration settings of all the installed servers.
2.
Modify the iDRAC network settings as required for the server(s).
NOTE: You must select the Enable LAN option to specify the IPv4 or IPv6 settings. For information about the
Online Help .
fields, see the
3.
To deploy the setting to iDRAC, click Apply iDRAC Network Settings. Any changes made to the QuickDeploy
Settings are also saved.
The iDRAC Network Settings table reflects future network configuration settings; the values shown for installed
servers may or may not be the same as the currently installed iDRAC network configuration settings. Click Refresh
to update the iDRAC Deploy page with each installed iDRAC network configuration settings after changes are
made.
NOTE: Changes made to QuickDeploy fields are immediate, but changes made to one or more iDRAC server
network configuration settings may require a couple of minutes to propagate from CMC to iDRAC. Clicking
Refresh too soon may display only partially correct data for a one or more iDRAC servers.

Modifying iDRAC Network Settings Using RACADM

RACADM config or getconfig commands support the -m <module> option for the following configuration
groups:
cfgLanNetworking
cfgIPv6LanNetworking
cfgRacTuning
cfgRemoteHosts
cfgSerial
cfgSessionManagement