Viewing World Wide Name/Media Access Control (Wwn/Mac) Ids; Command Messages - Dell PowerEdge VRTX User Manual

Chassis management controller version 1.0 for dell poweredge vrtx user's guide
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Viewing World Wide Name/Media Access Control (WWN/MAC) IDs

The WWN/MAC Summary page allows you to view the WWN configuration and MAC address of a slot in the chassis.
Fabric Configuration
The Fabric Configuration section displays the type of Input/Output fabric that is installed for Fabric A. A green check
mark indicates that the fabric is enabled for FlexAddress. The FlexAddress feature is used to deploy chassis assigned
and slot persistent WWN/MAC addresses to various fabrics and slots within the chassis. This feature is enabled on a
per-fabric and per-slot–basis.
NOTE: For more information about the FlexAddress feature, see

Command Messages

The following table lists the RACADM commands and output for common FlexAddress situations.
Table 27. FlexAddress Commands and Output
Situation
SD card in the active CMC module is
bound to another service tag.
SD card in the active CMC module
that is bound to the same service tag.
SD card in the active CMC module
that is not bound to any service tag.
FlexAddress feature not active on the
chassis for any reason (No SD card
inserted/ corrupt SD card/ after
feature deactivated /SD card bound to
a different chassis).
Guest user attempts to set
FlexAddress on slots/fabrics.
Deactivating FlexAddress feature with
chassis powered ON.
Guest user tries to deactivate the
feature on the chassis.
140
Command
$racadm featurecard -s
$racadm featurecard -s
$racadm featurecard -s
$racadm setflexaddr [-f
<fabricName> <slotState>]
$racadm setflexaddr [-i
<slot#> <slotstate>]
$racadm setflexaddr [-f
<fabricName> <slotState>]
$racadm setflexaddr [-i
<slot#> <slotstate>]
$racadm feature -d -c
flexaddress
$racadm feature -d -c
flexaddress
About
FlexAddress.
Output
The feature card inserted
is valid and contains the
following feature(s)
FlexAddress: bound to
another chassis, svctag =
<Service tag Number> SD
card SN = <Valid flex
address serial number>
The feature card inserted
is valid and contains the
following feature(s)
FlexAddress: bound
The feature card inserted
is valid and contains the
following feature(s)
FlexAddress:not bound
ERROR: Flexaddress
feature is not active on
the chassis
ERROR: Insufficient user
privileges to perform
operation
ERROR: Unable to
deactivate the feature
because the chassis is
powered ON
ERROR: Insufficient user
privileges to perform
operation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents