Executing Power Control Operations On A Server; Executing Power Control Operations For Multiple Servers Using Cmc Web Interface; Executing Power Control Operations On The Iom; Executing Power Control Operations On Iom Using Cmc Web Interface - Dell PowerEdge VRTX User Manual

Chassis management controller version 1.0 for dell poweredge vrtx user's guide
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Executing Power Control Operations on a Server

You can remotely perform power management actions for multiple servers at a time or an individual server in the
chassis.
NOTE: To perform power management actions, you must have the Chassis Configuration Administrator privilege.
Executing Power Control Operations for Multiple Servers Using
CMC Web Interface
To execute power control operation for multiple servers using the Web interface:
1.
In the left pane, click Server Overview → Power.
The Power Control page is displayed.
2.
In the Operations column, from the drop-down menu, select one of the following power control operations for the
required servers:
No Operation
Power On Server
Power Off Server
Graceful Shutdown
Reset Server (warm boot)
Power Cycle Server (cold boot)
For information about the options, see the
3.
Click Apply.
A dialog box appears requesting for confirmation.
4.
Click OK to perform the power management action (for example, reset the server).

Executing Power Control Operations on the IOM

You can remotely reset or turn on an IOM.
NOTE: To perform power management actions, you must have the Chassis Configuration Administrator privilege.

Executing Power Control Operations on IOM Using CMC Web Interface

To execute power control operations on the I/O Module:
1.
In the left pane, click Chassis Overview → I/O Module Overview → Power.
2.
On the Power Control page, for the IOM, from the drop-down menu, select the operation you want to execute
(power cycle).
3.
Click Apply.
158
Online Help .

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents