All units shipped without factory supplied cords and plug assemblies must be
hardwired using flexible conduit to the terminal block located on the rear of the unit.
These units should be wired to NEC specifications.
installation of restraint devices.
Adequate means must be provided to limit the movement of this appliance without
depending on or transmitting stress to the electrical conduit. A restraint kit is provided
with the fryer.
If the restraint kit is missing contact your local Frymaster Factory
Authorized Service Center (FASC) for part number 810-3574.
If this equipment is wired directly into the electrical power supply, a means for
disconnection from the supply having a contact separation of at least 3-mm in all poles
must be incorporated in the fixed wiring.
This equipment must be positioned so that the plug is accessible unless other means
for disconnection from the power supply (e.g., a circuit breaker) is provided.
If the electrical power supply cord is damaged, it must be replaced by a Frymaster Dean
Factory Authorized Service Center technician or a similarly qualified person in order to
avoid a hazard.
If this appliance is permanently connected to fixed wiring, it must be connected by
means of copper wires having a temperature rating of not less than 167°F (75°C).