tension pointed to the left side of the cabinet. If necessary, raise the unit and rotate drain toward
the right side. The end of the drain should be extended away from the unit cabinet to ensure
steam doesn't rise into the cabinet interior.
For units equipped with casters, there are no built-in leveling devices. The floor where the unit
is to be installed must be level.
3. If so equipped, connect the water hose(s) to the fitting(s) at the rear of the unit and connect the
unit to the water supply.
Incoming water pressure for all units should be approximately 40 PSI (28.15 kg/cm
The maximum allowable incoming water pressure for all units is 80 PSI (56.3 kg/cm
The maximum allowable incoming water temperature for all units is 180ºF (82ºC).
To prevent back flushing, the connection piping should be installed with a vacuum breaker
or means of providing an air gap 1" (2.54 cm) above the cookpot rim.
NOTE: On units equipped with water hoses, the hoses come with a quick-disconnect coupling.
The quick disconnect may be attached to the unit or to the water supply line, or it may be left off
entirely, whichever you prefer. If the unit is to be moved frequently (for cleaning or preventive
maintenance), Frymaster recommends installing flexible water lines. If the cooker is hard-
plumbed then moved, the connections may loosen and eventually cause leaks. Whichever option
is chosen, Teflon thread-seal tape, Loctite™ PST56765, or equivalent thread sealer must be
used when installing the fittings.
NOTE: Depending on specific model ordered, either hot {max 180°F (82°C}) or cold water, or
both, may be connected to the unit. If available, connecting hot water will minimize the time
required to bring the unit to operating temperature when filling with fresh water.
4. Connect the desired drain plumbing to the drain valve.
2.4
Connecting to the Electrical Supply
This unit must be connected to the voltage and phase specified on the rating and serial
number plate located on the inside of the equipment door. To determine the appropriate
wire size, refer to the POWER REQUIREMENTS chart at the bottom of this page.
1. If the unit is not equipped with an installed power cord, open the door and remove the contactor
box cover. Position the unit to gain access to the rear and remove the lower back panel.
2. Install a CE-approved harmonized cord rated for a minimum of 32 amps
at 415 VAC minimum with 5 wires, including a neutral and ground. It
DANGER
Do not use a water jet to clean this appliance.
CAUTION
DANGER
WARNING
DANGER
2-3
2
).
2
).
CE Standard