Checking The Burner Manifold Gas Pressure - Frymaster BIH52 Series Service Manual

Frymaster gas fryer service manual
Hide thumbs Also See for BIH52 Series:
Table of Contents

Advertisement

4.
Remove the wire and blow through the tube to ensure it is clear.
5.
Reinstall the tube and bend it so that the opening is pointing downward.
3.4

Checking the Burner Manifold Gas Pressure

Frymaster recommends that ONLY qualified service personnel perform this task.
1. On non-CE fryers, ensure that the gas valve knob is in the OFF position.
2. Remove the pressure tap plug from the gas valve assembly.
Typical Non-CE
Valve Assembly
2. Insert the fitting for a gas pressure-measuring device into the pressure tap hole.
3. On non-CE fryers only, place the gas valve in the ON position.
4. Place the fryer power switch in the ON position. When the burner has lit and burned steadily for
at least one minute, compare the gas pressure reading to the pressure for the corresponding gas in
the appropriate table found on the following page.
DANGER
Honeywell
ON
OFF
Pressure Tap Plug
3-6
Typical CE Valve
Assembly

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mh52 series

Table of Contents