3.8.2 Troubleshooting the Gas Valve
CONTROLLER
For non-CE units, verify
gas valve is in ON
present across gas
valve main coil?
gas pressure in
accordance with tables in
of this manual?
gas pressure in
accordance with tables on
of this manual?
Gas valve is OK>
IS CALLING
FOR HEAT.
position.
Is 24VAC
No
Yes
Is incoming
No
Section 2.3
Yes
Is outgoing
No
page 3-7
Yes
Problem is with 24VAC Circuit.
Refer to "Troubleshooting the
24VAC Circuit" on page 3-30.
Problem is with
gas supply to fryer.
Probable cause is misadjusted
or failed gas valve. Adjust gas valve in
accordance with Section 3.4 of this
manual. If valve cannot be
adjusted, replace valve.
3-33