Maximum value of set temperature
This is the maximum setpoint achievable in normal heating operation – Fig. 62.
Factory setting:
75 °C
Setting range:
60 – 75 °C
Set temperature ext. heating requirement
This is the set temperature for external heating requirement – Fig. 63.
Factory setting:
70 °C
Setting range:
35 – 75 °C
Type of pellet feed system
Setting whether: operation without feed system, with 3 or 2 wands or with
mixer (buried tank) – Fig. 64.
Factory setting: without feed system
Operating time of suction turbine
Factory setting:
Setting range:
50 – 120 s
Profile ash removal
This adjuster can be used to adjust the ash removal from the burner pot for
different levels of pellet quality – Fig. 66.
Level 0: very low proportion of ash – no ash removal in modulation mode.
to
Level 3: very high proportion of ash (possibly formation of slag) – frequent ash
removal in modulation mode
Factory setting: Level 1
Restore factory setting for next delivery of pellets.
Correction of cleaning interval
The cleaning interval is basically dependent on the proportion of ash in the
pellets and the ash removal profile. This adjuster can be used to extend or shor-
ten the cleaning interval by ±50 %.
The standard setting is a cleaning interval determined by testing. – Fig. 67.
Factory setting:
Setting range:
±50 %
If too long a cleaning interval is selected, the ash container may over-
fill.
80 s
0 %
41
Maximum value of
set temperature
75
Save
Fig. 62
Yes
No
Set temperature ext.
heating requirement
70
Save
Fig. 63
Yes
No
Pellet feed system
without feed system
Suction turb. 3 probes
Suction turb. 2 probes
Suction turbine mixer
Save
Yes
No
Fig. 64
Operating time of
suction turbine
80
Save
Fig. 65
Yes
No
Ash removal
Level 0
Level 1
Level 2
Level 3
Save
Fig. 66
Yes
No
Correction of
cleaning interval
Actual value
min.
-50 %
max.
+50 %
Save
Fig. 67
Yes
No
°C
+ +
°C
+ +
s
+ +
0 %
+ +