Scanning The Heat Yield And Temperatures - Viessmann VITOSOLIC 200 Installation And Service Instructions Manual

Electronic temperature differential control unit
Table of Contents

Advertisement

Service scans
Scanning the statement
"Solar statement:"
Colmax
Col2max
Cylmax
Cyl2max
Cyl3max
Cyl4max
Relay 1
to
Relay 7
Days
To reset the values, except for days
run:
Whilst this value is displayed, press the
following keys:
1. OK "Delete?""Yes" is displayed.

Scanning the heat yield and temperatures

For a description of the heat statement,
see from page 141.
Main menu
■ "HM"
■ "HM 1"
or
"HM 2"
■ "Tflow" (heat meter flow temperature)
■ "Tretn" (heat meter return tempera-
ture)
■ "Heat"
Note
Add the values for Wh, kWh and MWh
together.
86
(cont.)
Explanation
°C Maximum collector temperature, collector array 1
°C Maximum collector temperature, collector array 2
°C Maximum DHW cylinder temperature
°C Maximum cylinder temperature, consumer 2
°C Maximum cylinder temperature, consumer 3
°C Maximum cylinder temperature, consumer 4
h Hours run for relays R1 to R7
– Days run, solar control unit
2. OK to confirm.
Resetting the amount of heat
Whilst this value is displayed, press the
following keys:
1. OK "Delete?""Yes" is displayed.
2. OK to confirm.