Installing The Connection Set And Collector Temperature Sensor - Viessmann Vitosol-F Type SV Installation Instructions Manual

Flat-plate collector for sloping roofs type sv and sh
Hide thumbs Also See for Vitosol-F Type SV:
Table of Contents

Advertisement

Fitting collectors
Type
r
Quantity
1
SV
21
SH
21
Connection pipes should not show any
signs of damage.
Lubricate all plug-in connectors (O-
rings) found on the collectors only with
the special grease supplied with the con-
nection set.
The side with the type plate must be on
the outside of the first and last collec-
tor.
Secure the pipework on only one collec-
tor opposite the side with the type
plate.
1. Hook the collector into the mounting
plates and position the collector on
the mounting rails.
2. Secure the collector with four clamp-
ing brackets to the mounting rails.

Installing the connection set and collector temperature sensor

Observe the following when installing the
locking ring fitting:
■ All pipes must be cut at a right angle
and deburred.
■ Push the union nut and the locking ring
onto the pipe and lightly lubricate the
threads with oil.
20
(cont.)
2
3
4
21
31.5
31.5
31.5
42
52.5
3. Insert the connecting pipes into the
4. Hook in the next collector.
5. Carefully push the new collector
6. Install further collectors as descri-
7. Tighten all clamping brackets.
8. Fit the caps (part of the connection
■ Push the pipe into the locking ring fit-
ting as far as it will go.
■ Initially turn the union nut by hand,
then tighten with an open ended span-
ner by a further ¾ turn.
Never fit annealed copper pipes onto the
locking ring fittings.
5
6
8
42
42
63
73.5
flow and return connections.
against the first one and insert the
connecting pipes.
Distance to the bottom edge of the
fitted collector 21 mm.
bed.
set).
mm
10
52.5
63
94.5
115.5