Fitting roof hooks or clamping brackets

Fitting roof hooks for roof tiles

2.
3
30 x 100
1
38 x 58
1
1. Push up the roof tiles in accordance
with the dimensions shown in the
illustration on page 6.
2. Secure the timber to the joists at the
head of the exposed rows of tiles in
accordance with the dimensions
shown in the illustration on page 6.
3. Hook the roof hooks into the timber in
accordance with the following dimen-
sions:
■ for normal snow loads, see the dia-
gram on page 8 or 11
■ for higher snow loads, see the
dimensions on page 9 or 12.
5.
3
2
4.
4. Remove the drip tabs and protrusions
5. Secure the roof hooks and position
(cont.)
4
1.
3.
from the roof tiles where the roof
hooks are to be fitted.
the roof tiles.
Continue with "Mounting rail installa-
tion" on page 18.