Installation instructions

for contractors
Vitosol-F
Type SV and SH
Flat-plate collector for installation on supports and wall mounting
VITOSOL-F
Dispose after installation.
5592 924 GB
9/2010

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann Vitosol-F

  • Page 1: Installation Instructions

    VIESMANN Installation instructions for contractors Vitosol-F Type SV and SH Flat-plate collector for installation on supports and wall mounting VITOSOL-F Dispose after installation. 5592 924 GB 9/2010...
  • Page 2: Safety Instructions

    Safety instructions Please follow these safety instructions closely to prevent accidents and mate- rial losses. Safety instructions explained Working on the system Please note ■ Isolate the system from the power sup- This symbol warns against the ply and check that it is no longer 'live', risk of material losses and envi- e.g.
  • Page 3: Table Of Contents

    Index Installation sequence Installation on supports..................■ Components Vitosol-F, type SH................ ■ Components Vitosol-F, type SV................ ■ Determining collector row clearance z.............. ■ Installation of the collector supports and adjustment of the angle of inclination α ■ Installation on a substructure, e.g. steel beam..........
  • Page 4: Installation On Supports

    Installation on supports Components Vitosol-F, type SH α= 25° α= 30° α= 50° α= 35° α= 55° α= 40° α= 60° α= 45° α= 65° α= 70° α= 75° α= 80° α α Ø 11 M8x20 M8x25 A Collector support, angle of inclina- B Collector support, angle of inclina- tion α...
  • Page 5 Installation on supports (cont.) qW Cross brace qE Support rail (only for roofs with gravel ballast) Connection pipe rP Connection pipe rQ Special valve grease...
  • Page 6: Components Vitosol-F, Type Sv

    Installation on supports (cont.) Components Vitosol-F, type SV Ø 11 α= 60° α= 55° α= 50° α= 45° α= 40 α= 35° α= 30° α= 25° α M8x20 M8x25 1 Collector support 7 Hexagon bolt M 8 x 20 2 Base rail...
  • Page 7: Determining Collector Row Clearance Z

    Installation on supports (cont.) Connection pipe rP Connection pipe rQ Special valve grease Determining collector row clearance z When installing several collectors in ser- ies, maintain a clearance of z to prevent undesirable shading. α α β β Angle of the sun z Collector row clearance α...
  • Page 8: Installation Of The Collector Supports And Adjustment Of The Angle Of Inclination Α

    Installation on supports (cont.) Angle of inclination α Clearance between collector rows z in mm Type SV Type SH 50° 8190 3640 60° 8720 3870 Munich 25° 5160 2290 35° 6030 2680 45° 6710 2980 50° 6980 3100 60° 7350 3260 Installation of the collector supports and adjustment of the angle of inclination α...
  • Page 9: Installation On A Substructure, E.g. Steel Beam

    Installation on supports (cont.) Installation on a substructure, e.g. steel beam Installation information: ■ The side with the type plate must be ■ Observe the max. load and distance on the outside of the first and last col- from the edge of the roof for the on-site lector (see diagram on page 11).
  • Page 10 Installation on supports (cont.) Ø 8,5 qQ 9 Use the base rails as a drilling template. Type mm y 1920...
  • Page 11 Installation on supports (cont.) C Spacer lip D Type plate Continue with "installing the connection set and collector temperature sensor".
  • Page 12: Installation On Concrete Slabs, Only For Type Sh

    Installation on supports (cont.) Installation on concrete slabs, only for type SH Installation information: ■ The side with the type plate must be ■ Observe the max. load and distance on the outside of the first and last col- from the edge of the roof for the on-site lector (see diagram on page 15).
  • Page 13 Installation on supports (cont.) Use the base rails as a drilling template.
  • Page 14 Installation on supports (cont.) Ø 8,5 Note With angles of inclination of 25 and 30°, the front support rails can be secured in the centre.
  • Page 15 Installation on supports (cont.) C Spacer lip D Type plate Continue with "installing the connection set and collector temperature sensor".
  • Page 16: Wall Mounting (Only For Type Sh)

    Wall mounting (only for type SH) Components Ø 11 γ γ= 10° γ= 15° γ= 20° γ= 25° γ= 30° γ= 35° γ= 40° γ= 45° M8x20 M8x25 1 Collector support 7 Hexagon nut M 8 2 Base rail 8 Hexagon bolt M 8 x 20 3 Adjustable support 9 Hexagon bolt M 8 x 25 4 Gusset plate with circular hole...
  • Page 17: Installation Of The Collector Supports And Adjustment Of The Angle Of Inclination Γ

    Wall mounting (only for type SH) (cont.) Connection pipe rP Connection pipe rQ Special valve grease Installation of the collector supports and adjustment of the angle of inclination γ Trim the adjustable supports in accordance with the required angle of inclination (see page 16).
  • Page 18: Installing The Collectors

    Wall mounting (only for type SH) (cont.) Installing the collectors Installation information: ■ Gusset plate with circular hole at top ■ Gusset plate with slot at bottom ■ Secure the connection brace onto the retaining brackets between the sec- ond and third, the fourth and fifth supports, etc.
  • Page 19 Wall mounting (only for type SH) (cont.) qWqP Use the base rails as a drilling template.
  • Page 20 Wall mounting (only for type SH) (cont.) C Spacer lip D Type plate...
  • Page 21: Installing The Connection Set And Collector Temperature Sensor

    Installing the connection set and collector temperature sensor Components Connection set zP Connection pipe (short) zR Profile clip zQ Connection pipe (long) zT Support sleeve zW Plug zZ Special valve grease zE Locking ring fitting (angle), 7 22 mm, 90° Sensor well set uP Support sleeve uE Strain relief fitting...
  • Page 22 Installing the connection set and collector… (cont.) Never fit annealed copper pipes onto the locking ring fittings. zT K H Flow connection K Return connection...
  • Page 23: Installation

    "Vitosol" there. Metal seal connections, locking service instructions. ring fittings or Viessmann plug-in con- nections with double O-rings are the ■ If operating without a Solar-Divicon, most suitable. only use safety valves designed for If other seals such as flat gaskets are 120 °C, a maximum pressure of 6 bar,...
  • Page 24: Commissioning And Adjustment

    K Fill valve (F, G, L) C Drip container L Drain D Expansion vessel M Air separator E Stagnation heat sink N DHW cylinder F Shut-off valve O Solar control unit G Filling P Air vent valve Commissioning and adjustment Serviceanleitung "Vitosol-F".
  • Page 28 Viessmann Werke GmbH&Co KG Viessmann Limited D-35107 Allendorf Hortonwood 30, Telford Telephone: +49 6452 70-0 Shropshire, TF1 7YP, GB Fax: +49 6452 70-2780 Telephone: +44 1952 675000 www.viessmann.com Fax: +44 1952 675040 E-mail: info-uk@viessmann.com...

Table of Contents