Information regarding design and operation
Vitosol 200-T (pitched roof, flat roof, elevated)
Single-sided connection from below (preferred version)
1 collector array
A
With this connection, the "relay kick" function on the Vitosolic 200 must
be enabled (see chapter "Functions" in the "Solar control units" sec-
tion).
A Collector temperature sensor in the flow line
2 or more collector arrays (≥ 4 m
12
With this connection, the "relay kick" function on the Vitosolic 200 must
be enabled (see chapter "Functions" in the "Solar control units" sec-
tion).
A Collector temperature sensor in the flow line
Installation examples (hydraulic connection) Vitosol 200-T, type SP2
Take ventilation into consideration when designing the collector arrays
(see chapter "Ventilation" on page 128).
VIESMANN
122
2
)
A
(cont.)
2 and more collector arrays
A
A Collector temperature sensor in the flow line
Connection on both sides (crossflow)
A
With this connection, the "relay kick" function on the Vitosolic 200 must
be enabled (see chapter "Functions" in the "Solar control units" sec-
tion).
A Collector temperature sensor in the flow line
VITOSOL