For DHW heating in conjunction with boilers and district heating sys-
tems, as option with electric heater as accessory for DHW cylinders
with 300 and 500 l capacity.
Suitable for the following systems:
■ DHW temperatures up to 95 °C
■ Heating water flow temperature up to 160 °C
Capacity
DIN reg. no.
Continuous output
for DHW heating from 10 to 45 °C
and a heating water flow tempera-
ture of ... at the heating water
throughput stated below
Continuous output
for DHW heating from 10 to 60 °C
and a heating water flow tempera-
ture of ... at the heating water
throughput stated below
Heating water flow rate for the stated contin-
uous outputs
Standby heat loss q
BS
at a temp. differential of 45 K (actual value acc.
to DIN 4753-8.
500 l: Standard parameter to DIN V 18599)
Thermal insulation
Dimensions
Length (7)
– incl. thermal insulation
– excl. thermal insulation
Width
– incl. thermal insulation
– excl. thermal insulation
Height
– incl. thermal insulation
– excl. thermal insulation
Height of unit when tilted
– incl. thermal insulation
– excl. thermal insulation
Installation height
Weight including thermal insulation
Heating water content
Heating surface
Connections
Heating water flow and return
Cold water, DHW
DHW circulation
Information regarding continuous output
When designing the system for continuous output as stated or calcu-
lated, allow for the corresponding circulation pump. The stated con-
tinuous output is only achieved when the rated boiler output
uous output.
VITOSOL
l
160
90 °C
kW
40
l/h
982
80 °C
kW
32
l/h
786
70 °C
kW
25
l/h
614
60 °C
kW
17
l/h
417
50 °C
kW
9
l/h
221
90 °C
kW
36
l/h
619
80 °C
kW
28
l/h
482
70 °C
kW
19
l/h
327
3
3.0
m
/h
kWh/
1.50
24 h
Rigid PUR foam
a
mm
581
mm
b
mm
608
mm
c
mm
1189
mm
mm
1260
mm
mm
kg
86
l
5.5
2
1.0
m
R
1"
R
¾"
R
¾"
≥ contin-
■ Operating pressure on the heating water side up to 25 bar
■ Operating pressure on the DHW side up to 10 bar
200
300
0241/06–13 MC/E
40
53
982
1302
1720
32
44
786
1081
1425
25
33
614
811
1106
17
23
417
565
9
18
221
442
36
45
619
774
28
34
482
584
19
23
327
395
3.0
3.0
1.70
2.20
Flexible polyurethane foam
581
633
608
705
1409
1746
1955
1844
1460
1792
1860
2045
97
151
5.5
10.0
1.0
1.5
1"
1"
¾"
1"
¾"
1"
500
750
1000
70
123
136
3022
3341
58
99
111
2432
2725
45
75
86
1843
2113
32
53
59
786
1302
1450
24
28
33
589
688
810
53
102
121
911
1754
2081
44
77
91
756
1324
1565
33
53
61
567
912
1050
3.0
5.0
5.0
3.20
3.70
4.30
850
960
1060
650
750
850
898
1046
1144
837
947
1047
2100
2160
2005
2060
2050
2100
2190
2250
181
295
367
12.5
24.5
26.8
1.9
3.7
4.0
1"
1¼"
1¼"
1¼"
1¼"
1¼"
1"
1¼"
1¼"
VIESMANN