Installation Examples - Viessmann Vitosol 200-T SP2A Technical Data Manual

Vacuum tube collector based on the heat pipe principle for the utilisation of solar energy
Hide thumbs Also See for Vitosol 200-T SP2A:
Table of Contents

Advertisement

Vitosol 200-T, SP2A Technical Data

Installation Examples

Take venting into account when engineering the collector array.
2
Note: Max. 161 ft
(15 m
be connected in series to form a single array.
Vertical installation on sloped roofs, horizontal installation
or installation on supports
Single row installation; connection from the left or right
A Collector temperature sensor
Installation in several rows, connection from the left or right
A Collector temperature sensor
2
) absorber collector area can
Horizontal installation on a sloped roof or wall mount.
Single sided connection from below required. U-pipe
fitting with integrated air vent must be used.
1 collector array
With this type of connection, the "Evacuated tube
collector" function at the SCU control must be enabled.
A Collector temperature sensor
2 or more collector arrays (≥4m
With this type of connection, the "Evacuated tube
collector" function at the SCU control must be enabled.
A Collector temperature sensor
Design Information
2
)
9 9