Information regarding design and operation
A Connecting brace
B Connecting tie
Collector type x
mm y
SV
595
SH
1920
Ballast and max. load on the substructure
Calculation in accordance with DIN 1055-4, 3/2005 and DIN 1055-5,
7/2005.
Two foot support slabs each A and B are required respectively for each
collector.
Vacuum tube collectors Vitosol 200-T and Vitosol 300-T (elevated installation)
Information on Vitosol 200-T, type SD
Never select this type of installation if the solar thermal system is to be
used for central heating backup (see also product description in chap-
ter "Vitosol 200-T").
VITOSOL
(cont.)
C Foot support A
D Foot support B
mm z
481 See page 110.
481 See page 110.
Note
For the calculation, the Viessmann "SOLSTAT" calculation program is
available at "www.viessmann.com".