VIESMANN Installation instructions for contractors Vitosol 200-F Type SVKA Flat-plate collector for pitched roofs, roof integration VITOSOL 200-F Dispose after installation. 5793 148 GB 2/2014...
Page 2
Safety instructions Please follow these safety instructions closely to prevent accidents and mate- rial losses. Safety instructions explained Working on the system Please note ■ Isolate the system from the power sup- This symbol warns against the ply (e.g. by removing the separate fuse risk of material losses and envi- or by means of a mains isolator) and ronmental pollution.
Index Intended use....................... Installation sequence Components......................Installation information..................Installing the collectors..................Fitting the covers....................16 Commissioning..................... 21...
Intended use The appliance is only intended to be installed and operated in sealed unven- ted systems that comply with EN 12828 / DIN 1988, or solar thermal systems that comply with EN 12977, with due atten- tion paid to the associated installation, service and operating instructions.
Components 1 Timber qQ Centre clamp 120 x 30 x 2500 mm qW Left hand side panel 2 Screws 8 x 120 mm (for roof tiles and barrel roof tiles 3 Timber with sealing strips) 48 x 30 x 2500 mm qE Left hand flashing 4 Nails qR Centre panel...
Components (cont.) qI Top panel (for roof tiles and barrel roof tiles with sealing strips) qO Lower flashing Installation information Required roof area: 2700 x 2700 mm ■ Provide a roof hatch near the collec- ■ To prevent any damage to the ridge tors for inspection and maintenance.
Installing the collectors ■ Provisionally position the lower timber ■ If cantilevers are created, support parallel to the lower row of tiles (tie a them with an on-site batten. line as a guide). ■ It is essential to secure timbers along ■...
Page 11
Installing the collectors (cont.) 6x30 6x30 Information on step 9: The collector temperature sensor is part Do not tighten the screws yet, as the of the standard delivery of the connec- second collector must be pushed under tion set. the clamp. Please note Connection pipes must not show any signs of damage.
Page 12
Installing the collectors (cont.) Connecting the connection set A Connection, tee (S-shape) with sen- B Connection, tee (return) sor well for collector temperature sensor (flow)
Page 13
Installing the collectors (cont.) Fitting the collector temperature sensor...
Page 15
Installing the collectors (cont.) Installing the second collector Ø6 6x30 Information on step 19: Information on step 22: Push the second collector under the cen- Drill 2 holes in the lower edge of each tre clamps (see diagram on page 11). collector (water drainage).
Page 20
Fitting the covers (cont.) Tiled roof cover Trim the tiles to size or use half-sized tiles. Remove tile head A which rests on the side panel. Please note The diagonal sealing strip must be completely covered. If necessary, trim the top of the diagonal sealing strip with a knife.
Fitting the covers (cont.) Barrel roof tile cover Slate and plain tile cover Position slates and plain tiles up to the central edge of the side sections. Commissioning "Vitosol-F" service instructions.