Viessmann Vitosol 200-F Installation Instructions For Contractors

Viessmann Vitosol 200-F Installation Instructions For Contractors

Flat-plate collector for pitched roofs, roof integration

Advertisement

Quick Links

VIESMANN
Installation instructions
for contractors
Vitosol 200-F
Type SVKA
Flat-plate collector for pitched roofs, roof integration
VITOSOL 200-F
Dispose after installation.
5793 148 GB
2/2014

Advertisement

loading

Summary of Contents for Viessmann Vitosol 200-F

  • Page 1 VIESMANN Installation instructions for contractors Vitosol 200-F Type SVKA Flat-plate collector for pitched roofs, roof integration VITOSOL 200-F Dispose after installation. 5793 148 GB 2/2014...
  • Page 2 Safety instructions Please follow these safety instructions closely to prevent accidents and mate- rial losses. Safety instructions explained Working on the system Please note ■ Isolate the system from the power sup- This symbol warns against the ply (e.g. by removing the separate fuse risk of material losses and envi- or by means of a mains isolator) and ronmental pollution.
  • Page 3: Table Of Contents

    Index Intended use....................... Installation sequence Components......................Installation information..................Installing the collectors..................Fitting the covers....................16 Commissioning..................... 21...
  • Page 4: Intended Use

    Intended use The appliance is only intended to be installed and operated in sealed unven- ted systems that comply with EN 12828 / DIN 1988, or solar thermal systems that comply with EN 12977, with due atten- tion paid to the associated installation, service and operating instructions.
  • Page 5: Components

    Components 1 Timber qQ Centre clamp 120 x 30 x 2500 mm qW Left hand side panel 2 Screws 8 x 120 mm (for roof tiles and barrel roof tiles 3 Timber with sealing strips) 48 x 30 x 2500 mm qE Left hand flashing 4 Nails qR Centre panel...
  • Page 6: Installation Information

    Components (cont.) qI Top panel (for roof tiles and barrel roof tiles with sealing strips) qO Lower flashing Installation information Required roof area: 2700 x 2700 mm ■ Provide a roof hatch near the collec- ■ To prevent any damage to the ridge tors for inspection and maintenance.
  • Page 7: Installing The Collectors

    Installing the collectors ■ Provisionally position the lower timber ■ If cantilevers are created, support parallel to the lower row of tiles (tie a them with an on-site batten. line as a guide). ■ It is essential to secure timbers along ■...
  • Page 8 Installing the collectors (cont.) 8x120...
  • Page 9 Installing the collectors (cont.) 6x30...
  • Page 10 Installing the collectors (cont.) 6x30...
  • Page 11 Installing the collectors (cont.) 6x30 6x30 Information on step 9: The collector temperature sensor is part Do not tighten the screws yet, as the of the standard delivery of the connec- second collector must be pushed under tion set. the clamp. Please note Connection pipes must not show any signs of damage.
  • Page 12 Installing the collectors (cont.) Connecting the connection set A Connection, tee (S-shape) with sen- B Connection, tee (return) sor well for collector temperature sensor (flow)
  • Page 13 Installing the collectors (cont.) Fitting the collector temperature sensor...
  • Page 14 Installing the collectors (cont.)
  • Page 15 Installing the collectors (cont.) Installing the second collector Ø6 6x30 Information on step 19: Information on step 22: Push the second collector under the cen- Drill 2 holes in the lower edge of each tre clamps (see diagram on page 11). collector (water drainage).
  • Page 16: Fitting The Covers

    Fitting the covers Information on step 2: Move the side panels right up to the col- lector edge.
  • Page 17 Fitting the covers (cont.) Information on step 4: Move the top section right up to the col- lector edge.
  • Page 18 Fitting the covers (cont.)
  • Page 19 Fitting the covers (cont.)
  • Page 20 Fitting the covers (cont.) Tiled roof cover Trim the tiles to size or use half-sized tiles. Remove tile head A which rests on the side panel. Please note The diagonal sealing strip must be completely covered. If necessary, trim the top of the diagonal sealing strip with a knife.
  • Page 21: Commissioning

    Fitting the covers (cont.) Barrel roof tile cover Slate and plain tile cover Position slates and plain tiles up to the central edge of the side sections. Commissioning "Vitosol-F" service instructions.
  • Page 24 Viessmann Werke GmbH&Co KG Viessmann Limited D-35107 Allendorf Hortonwood 30, Telford Telephone: +49 6452 70-0 Shropshire, TF1 7YP, GB Fax: +49 6452 70-2780 Telephone: +44 1952 675000 www.viessmann.com Fax: +44 1952 675040 E-mail: info-uk@viessmann.com...