Tascam DR-60D Owner's Manual page 47

Linear pcm recorder
Hide thumbs Also See for DR-60D:
Table of Contents

Advertisement

4.
Turn the DATA dial to set the mic input gain.
Options:
(default value),
LOW
NOTE
has only two mic input gain options—
Ch3/4
and
.
HIGH
The
,
and
settings change the input gain, and
LOW
MID
HIGH
should be set according to the input level.
If you are not sure which setting to use, try
level is too low even after adjustment, return to the
screen and set it to
SETTING
to
.
HIGH
The limiter function can be set and changed even during
recording standby and when recording.
When finished making the setting, press the stop (8) [HOME]
5.
button to return to the Home Screen.
Press the record (0) button to begin recording standby.The
6.
record indicator flashes red and the recording screen appears.
,
MID
HIGH
(default value)
LOW
first. If the input
LOW
INPUT
. If the level is still too low, set it
MID
7.
Use the 1/L, 2/R and 3-4 knobs on the front of the unit to adjust
the input levels.
If the input levels are too high, the peak indicators to the left of
the 1/L, 2/R and 3-4 knobs light red.
A b mark is provided at –12 dB on the level meters. Set the
input level so that the indicator bars move to and fro with this
mark at about the center without causing the 1/L knob, 2/R
knob, 3-4 knob PEAK indicator to light red when the loudest
sounds occur.
CAUTION
During mic input, this lights if distortion occurs in the analog
circuitry. During line level input, this does not light even if
distortion occurs in the analog circuitry.
NOTE
To monitor the sound while adjusting the input levels or
recording, connect headphones to the PHONES jack.
Use the PHONES jack volume control to adjust the monitoring
level. Changing the monitoring volume does not affect the
recorded sound.
8.
When finished making the setting, press the stop (8) [HOME]
button to exit recording standby.
4 – Recording
47
TASCAM DR-60D

Advertisement

Table of Contents
loading