The data string is further defined as follows:
Ax Bx Ay By A/B 9 A/B 0
where: Ax Bx = data string for ATTEN X
(x can be none, one or more of the digits 1, 2, 3, or 4)
Ay By = data string for ATTEN Y
(x can be none, one or more of the digits 5, 6, 7, or 8)
Note that if Ax (Ay) uses a digit, then that digit may not be used in Bx
(By).
A/B 9 = GPIB command for switch S9
A/B 0 = GPIB command for switch S0
The data string contains the operation selected by the user (desired
contact closure, value of attenuation, etc.). The coded command from
the controller is converted by the driver into control voltages. The
output control voltages drive the device and illuminate front panel
lights that indicate the operation selected.
Table 6-2 shows the relationship between each programming code and the
effect it has on the output at each connector/pin.
Table 6-3 shows the programming strings required to set up various three
and four-section attenuators to the desired levels of attenuation.
Program Execution Time
The response time for the driver is defined as the time between data
valid (DAV) changing from a high to a low and the output signal at the
rear panel connector changing state. The switching speed of the Agilent
Technologies programmable attenuators is 20 ms including 10 ms for
the driver (ATTEN outputs). The switching speed for the RF switches is
20 to 50 ms plus 20 ms for the driver (S9 and S0 outputs).

Sending the Data Message

The driver does not have the capability of sending a data message.

Receiving the Trigger Message

The driver does not respond to the Trigger message.

Receiving the Clear Message

The remote message causes the driver to switch to the remote mode.
The remote message has two parts: the remote enable (REN) and
address-to-listen. The driver's outputs do not change with the
local-to-remote transition. The REMOTE LED turns on when the driver
is in remote mode.