[22]Miscellaneous Features 1
(1) Abort Delay - Program to allow a 15
second Delay (except 24 Hour Zones ) after
a zone trip before reporting.
Disarm the

system within 15 seconds to prevent report-
ing.
(2)
Easy
Exit/Easy
Arm-
command. While the system is
armed, entering this command allows 3 min-
utes to Exit through Exit/Entry and Exit/Entry
Follower Zones . Enabling this option also

enables Easy Arm, press the
the system.
(3) Swinger Shutdown - Automatically dis-
ables armed zones with excessive alarm/
restores (swingers). Non-24-Hour Protection
zones: allows only 3 alarms and 2 restores
per zone per arming before the zone is dis-
abled.
(4) Bell on Line Cut (Armed) - Program to
turn the Bell Output on if the telephone line
has been cut while the panel is armed.
[23]Programmable Output Features 1
(1) Audio Verification - Program to activate
the PGM during reporting. Select specific
zones for audio verification by programming
the required zones in PGM Output [08],
PGM Features 2 [24] and PGM Features 3
[25]. Connect the PGM to the Veriphone
trigger low input.
(2) Access Output - Activates the PGM
Wi850a
page 15
output for 5 seconds using the
command.
(3) Follow Keypad Sounder - The follow-
ing keypad sounds will activate the PGM
output:
Entry Sounder, Keypad Pulsing
Sounder, Keypad Output on Alarm, Chime,
Enables
Fault Find.
(4) Keyfob/Keyswitch Chirp - Program to
chirp the PGM Output (1) one time when
the panel is armed or (2) two times when
the panel is disarmed. Wire as shown in
Figure 7.
key to arm
BLK
PGM
RED
+AUX
COM
+AUX
7 K
/K
FIGURE
EYFOB
EYSWITCH
[24]Programmable Output Features 2
(1) Fire - Program to activate the PGM on a
Fire alarm.
(2) AUX - Program to activate the PGM on
a AUX alarm.
(3) Panic - Program to activate the PGM on
a Panic alarm.
TM
(4) Test Timer - Program to activate the
PGM during a Test Timer report.

[25]Programmable Output Features 3
(1) AC Fail - Program to activate the PGM on
the loss of AC. (15 minute delay)
(2) Low Battery - Program to activate the
PGM on a Low Battery condition.
(3) *Trouble - Program to activate the PGM
on a Trouble condition.
(4) Armed - Program to activate the PGM
when the panel is Armed. The PGM output
will flash when the panel has gone into
alarm.
*Includes Bell Cut, Fire Trouble, Receiver
Fail-to-Respond, Receiver Tamper, Receiver
K1
JAM, Wireless Smoke Low Battery, Wireless
Smoke Supervisory Fail.
[26]Miscellaneous Features 2
N/C
N/O
(1) Momentary Keyswitch Arming - Typi-
cally, connect a normally-open Keyswitch
Siren Driver
Steady Input
across the zone AND its 3.3K zone-doubling
resistor.
C
HIRP
(2) Reserved.
(3) Inhibit Fail-to-Communicate Display -
This option prevents the keypad from either
indicating or sounding when a Fail to Com-
municate has occurred.
(4) Inhibit Low Battery Display - Program
to inhibit the Low Battery Display at the
keypad. Low Battery Reporting is not inhib-
ited. The programming option is not permit-
ted for UL installations.