Teledyne 7500 Instruction Manual page 26

Infrared gas analyzer communication functions (modbus)
Hide thumbs Also See for 7500:
Table of Contents

Advertisement

Word data [read-out/write-in]: Function code [03
User settings
Relative
Register
Data
address
No.
type
0014
40021
Word
H
0015
40022
Word
H
0016
40023
Word
H
0017
40024
Word
H
0018
40025
Word
H
0019
40026
Word
H
001A
40027
Word
H
001B
40028
Word
H
001C
40029
Word
H
001D
40030
Word
H
001E
40031
Word
H
001F
40032
Word
H
0020
40033
Word
H
0021
40034
Word
H
0022
40035
Word
H
0023
40036
Word
H
0024
40037
Word
H
0025
40038
Word
H
0026
40039
Word
H
0027
40040
Word
H
0028
40041
Word
H
0029
40042
Word
H
002A
40043
Word
H
002B
40044
Word
H
002C
40045
Word
H
002D
40046
Word
H
002E
40047
Word
H
002F
40048
Word
H
0030
40049
Word
H
0031
40050
Word
H
0032
40051
Word
H
0033
40052
Word
H
0034
40053
Word
H
0035
40054
Word
H
0036
40055
Word
H
Memory contents
CH1 auto calibration switch
CH2 auto calibration switch
CH3 auto calibration switch
CH4 auto calibration switch
CH5 auto calibration switch
CH1 zero calibration switch
CH2 zero calibration switch
CH3 zero calibration switch
CH4 zero calibration switch
CH5 zero calibration switch
CH1 calibration range switch
CH2 calibration range switch
CH3 calibration range switch
CH4 calibration range switch
CH5 calibration range switch
CH1 range-1 high alarm setting
CH1 range-1 low alarm setting
CH1 range-2 high alarm setting
CH1 range-2 low alarm setting
CH2 range-1 high alarm setting
CH2 range-1 low alarm setting
CH2 range-2 high alarm setting
CH2 range-2 low alarm setting
CH3 range-1 high alarm setting
CH3 range-1 low alarm setting
CH3 range-2 high alarm setting
CH3 range-2 low alarm setting
CH4 range-1 high alarm setting
CH4 range-1 low alarm setting
CH4 range-2 high alarm setting
CH4 range-2 low alarm setting
CH5 range-1 high alarm setting
CH5 range-1 low alarm setting
CH5 range-2 high alarm setting
CH5 range-2 low alarm setting
26
Teledyne Analytical Instruments
, 06
, 10
]
H
H
H
Read-on / Write-in data
Remarks or
corresponding
parameter
0, 1
Auto calibration
(0: Dn not calibrate in
component
auto calibration
1: Calibrate in auto
calibration)
0, 1
About zero
(0: Selectable, zero
calibration
calibration
1: Zero calibration at
once)
0, 1
About calibration
(0: Calibrate indicated
range
range only
1: Calibrate both ranges
at the same time)
0 to 9999
Alarm setting
Decimal point position
depends on range
Relevant
model
R/K
R/K
R/K
R/K
K
R/K
R/K
R/K
R/K
K
R/K
R/K
R/K
R/K
K
R/K
R/K
R/K
R/K
R/K
R/K
R/K
R/K
R/K
R/K
R/K
R/K
R/K
R/K
R/K
R/K
K
K
K
K