To meet warranty requirements, supply water must meet the following specification:
Total Dissolved Solids (TDS)............60 PPM or less
Hardness...........................................2 Grains (35 PPM) or less
pH Factor ..........................................7.0 to 7.5
Chlorine and/or bromine ...................1 PPM or less
S
TARTUP
Turn control lever to ON position and set the Cook-Idle switch to COOK MODE (see Figure 3). The steamer will fill
automatically and be ready for cooking in about four minutes.
O
PERATION
HOT STEAM WILL ESCAPE WHEN DOOR IS BEING OPENED. TO PREVENT BURNS KEEP HANDS AND
FACE AWAY FROM STEAM.
To save water and electricity, set the Cook-Idle switch to IDLE MODE and/or turn the control lever to OFF when the
steamer is not in use. Idle Mode will hold the water temperature in the range 120°F to 190°F. When ready to cook,
set the Cook-Idle switch to COOK MODE and wait approximately 2-3 minutes before starting to cook food.
Suggested cooking times for various foods are shown in the table in the following section.
Pan specifications are shown on page 4.
The door may be opened or closed at any time. The steamer temporarily shuts off while the door is open.
Timer can be used as a reminder to the operator. The timer does NOT turn the steamer on or off!
S
HUTDOWN
Turn lever to the OFF position. The water in the bottom of the cavity will automatically drain.
T
ROUBLESHOOTING BY
The following table lists the possible causes and solutions of problems that may occur during operation.
Problem
Steamer does not heat up at all.
Steamer does heat up, but does not produce enough steam.
Steamer does not drain correctly.
O
'
WNER
S
S
OUNTERTOP
TEAMER
NOTICE: WATER SPECIFICATION
O
PERATOR
M
1189951 (10/08)
ANUAL
CAUTION
Possible Causes and Solutions
– Electric power is shut off. Turn on power.
– Water supply is shut off. Turn on water.
– Not enough water is entering steamer. Check water supply.
– Lime build-up. De-lime steamer cavity (see page 10).
– If water is OK and there is little lime build-up, call repair service.
– Door is open or ajar. Close steamer door completely.
– Steamer is in IDLE mode. Set Cook-Idle switch to COOK MODE
– Lime build-up. De-lime steamer cavity (see page 10).
– Not enough water. Check water supply.
– Clogged drain on inside of steamer cavity. Check and clear.
– Clogged drain outside of steamer. Check and clear.