Southbend StratoSteam STRE-3D Owner's Manual page 22

Countertop steamer
Hide thumbs Also See for StratoSteam STRE-3D:
Table of Contents

Advertisement

S
ERVICE
Figure 11
Steamer Not Heating Up, "Power" Light Is Not Lit
DISCONNECT POWER AT CIRCUIT BREAKER
Check resistance between heating-cartridge contactor terminals
as described on page 25.
Is measured resistance
No
in the range specified on
Disconnect all the heating
cartridges from the contactor.
Measure the resistance across
the leads each cartridge.
Replace any cartridge that
shows either an open or short
circuit.
P
22
56
AGE
OF
Steamer not heating up, "Power" light not lit.
DISCONNECT POWER AT CIRCUIT BREAKER
Remove right side panel for access.
Reconnect power at circuit breaker.
Turn lever to ON position and close door (to actuate door switch).
Check voltage between terminals L1 and L3 on contactor
No
voltage 208, 220, or 240
Yes
page 25?
Check main fuses (480V
models only) and replace as
needed.
S
TRATO
(see page 27).
Is measured
volts?
Test operation of power switch (see page 26). Replace if
necessary. If power switch is OK, replace "Power" light and follow
O
'
M
WNER
S
S
E
C
TEAM
LECTRIC
OUNTERTOP
Yes
procedure on page 23.
1189951 (10/08)
ANUAL
S
TEAMER

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stratosteam stre-5d