Southbend R18-4 Operator's Manual

Southbend R18-4 Operator's Manual

Electric counter convection steamer

Advertisement

IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this
manual for the life of the equipment:
Model #: __________________________
Serial #: __________________________
Date Purchased: ___________________
OPERATOR'S MANUAL
Electric Counter Convection Steamer
R18-4
!
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage,
injury or death. Read the installation, operating and maintenance instructions thoroughly before
installing or servicing this equipment.
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
www.southbendnc.com
HEAVY DUTY STEAM
M
1195735 R
0 (11/22/2011)
ANUAL
EV

Advertisement

Table of Contents
loading

Summary of Contents for Southbend R18-4

  • Page 1 Serial #: __________________________ Date Purchased: ___________________ OPERATOR’S MANUAL Electric Counter Convection Steamer R18-4 WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
  • Page 2 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 IMPORTANT NOTES FOR INSTALLATION AND OPERATION WARNING: This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
  • Page 3: Table Of Contents

    INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 TABLE OF CONTENTS DESCRIPTION PAGE 1.0 SERVICE CONNECTIONS ..........4 2.0 INTRODUCTION .
  • Page 4: Service Connections

    INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 1.0 SERVICE CONNECTIONS MANUAL 1195735 REV0 (11/22/2011) HEAVY DUTY STEAM...
  • Page 5: Introduction

    2.0 INTRODUCTION DESCRIPTION The model R18-4 steamer comes equipped with a standard 9 kW heating block that can be reduced to 6 kW on single phase supplies. Your new steamer has been designed and manufactured to meet the toughest industry standards.
  • Page 6: Installation

    INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 3.0 INSTALLATION UNPACKING Immediately after unpacking the steamer, check for possible shipping damage. If the steamer is found to be damaged after unpacking, save the packaging materials and contact the carrier within 15 days of delivery. File a claim regardless of extent of damage.
  • Page 7 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 3.0 INSTALLATION (Continued) PLUMBING CONNECTIONS WARNING: Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Connect the water supply line to the 3/8" compression tube inlet. The 3/8" water line supplies water to the cavity to generate steam or the user can manually supply water by filling through the cavity door.
  • Page 8: Performance Check

    INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 4.0 PERFORMANCE CHECK WARNING: The steamer and its parts are hot. Use care when operating, cleaning or servicing the steamer. The cooking compartment contains live steam and hot water. Stay clear while opening the door.
  • Page 9: Operating Instructions

    INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 5.0 OPERATING INSTRUCTIONS CONTROLS 1. Door Handle Move handle up to open door to cooking cavity. 2. Ready Pilot Light When lit, indicates the steamer cavity is above 150° F (65° C) and is ready for the cooking cycle.
  • Page 10 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 5.0 OPERATING INSTRUCTIONS (Continued) COOKING CAUTION: Live steam and accumulated hot water in the compartment may be released when the door is opened. Close drain valve. Remove the deflector plate to expose the bottom of the cavity.
  • Page 11 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 5.0 OPERATING INSTRUCTIONS (Continued) SHUTDOWN CAUTION: When the unit is not in use, leave the cooking compartment doors ajar to prolong the life of the door gasket. Drain the steamer after each day’s use.
  • Page 12 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 5.0 OPERATING INSTRUCTIONS (Continued) Inspect the drain opening to ensure there are no obstructions. Replace the pan supports and deflector in compartment and leave door ajar. WARNING: When this appliance is installed with casters and is...
  • Page 13: Cooking Guidelines

    INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 6.0 COOKING GUIDELINES Frozen vegetables should always be cooked in perforated 12" x 20" x 2 ½ “ (1/1 65 mm) pans, 7 ½ lbs. (3.4 kg) maximum per pan. Frozen entrees should be underlined with a perforated pan for best results. If they are defrosted first, the heating time will be decreased.
  • Page 14 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 6.0 COOKING GUIDELINES (Continued) 15. Eggs may be cooked out of the shell if they are to be chopped which eliminates peeling after steaming. 16. The steam cooker can be opened during the cooking period to add or remove items.
  • Page 15: Preventive Maintenance

    INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 7.0 PREVENTIVE MAINTENANCE A good preventive maintenance program begins with the daily cleaning procedure. Additional preventive maintenance operations are presented in this section. In establishments that employ full-time maintenance personnel, the tasks described can be assigned to them. For other installations, tasks requiring mechanical or electrical experience should be performed by an authorized service agency.
  • Page 16 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 7.0 PREVENTIVE MAINTENANCE (Continued) CLEANING Weekly, or more often if necessary: Clean exterior with a damp cloth and polish with a soft dry cloth. Use a non-abrasive cleaner to remove discolorations. It is NOT RECOMMENDED to use cleaning agents that are corrosive.
  • Page 17 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 7.0 PREVENTIVE MAINTENANCE (Continued) Set the power switch to “TIMED COOKING” and set the timer to 30 minutes. At the end of the 30 minute cook cycle, turn power switch “OFF” and drain the contents of the cavity.
  • Page 18: Troubleshooting

    INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 8.0 TROUBLESHOOTING GENERAL PROBLEM PROBABLE CAUSE REMEDY 1. C a. Main power circuit breaker Locate external circuit breaker for incoming OOKING INDICATOR tripped. power and place in ON position. LIGHT FAILS TO LIGHT...
  • Page 19 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 8.0 TROUBLESHOOTING (Continued) COMPONENT TESTING 60-MINUTE TIMER Timer Contacts Defective timer contacts will result in failure of cooker compartment to operate. When this occurs, remove the side panel and proceed as follows: 1.
  • Page 20 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 8.0 TROUBLESHOOTING (Continued) 3. Set timer dial (any setting beyond “0 - Minute”). If operation is correct, the motor will turn the dial toward “0 - Minute”. If the motor fails to operate, it is defective and the entire timer must be replaced.
  • Page 21 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 8.0 TROUBLESHOOTING (Continued) Wiring WARNING: Disconnect the power supply to the appliance before cleaning or servicing. Using an ohmmeter, wiring continuity between the connections shown on the wiring diagram is readily verified. This is best done in stages, removing only those wires required for each continuity check.
  • Page 22 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 8.0 TROUBLESHOOTING (Continued) Exterior Panel Removal WARNING: To prevent hazard in servicing the cooker, be certain that the electrical disconnect circuit breaker for the steamer is OFF before removing any panels. Access to all internal plumbing and electrical assemblies is from the right side. The right-side panel is removed by removing the bottom screws from panel.
  • Page 23: Wire Diagrams

    INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 9.0 WIRE DIAGRAMS MANUAL 1195735 REV0 (11/22/2011) HEAVY DUTY STEAM...
  • Page 24 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 MANUAL 1195735 REV0 (11/22/2011) HEAVY DUTY STEAM...
  • Page 25 INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODEL R18-4 MANUAL 1195735 REV0 (11/22/2011) HEAVY DUTY STEAM...

Table of Contents