Figure 7
Water Drain
S
4: W
C
TEP
ATER
ONNECTION
Do not connect steamer to a hot water line. A hot water connection will damage the steamer.
To meet warranty requirements, the supply water must meet the following specifications:
Pressure
Total Dissolved Solids (TDS)
Hardness
pH
Chlorine and/or bromine
Connect a cold water line to the water inlet strainer on the back of the steamer, as shown in Figure 6. The connector
on the steamer is a 1/4" (6 mm) compression fitting. (If the unit was ordered with the split-water-line option, connect
the treated-water supply to the lower inlet, and the regular-water supply to the upper inlet.)
NOTE: To facilitate cleaning, and allow access to rear of the steamer, flexible connections are recommended. A shut
off valve at (or near) the rear of the steamer is highly recommended. Also, an accessible water filter is recommended
to help keep water quality within the requirements described above. See Figure 8 below.
Figure 8

Water Connection

Cold
Water
Supply
P
16
56
AGE
OF
90°
Air Gap
Air Gap
NOTICE
Shut Off
Valve
S
S
TRATO
Air Gap
Floor Drains
WARNING
30 to 60 PSI (205 to 410 kPa)
60 PPM or less
2 grains (35 PPM) or less
7.0 to 7.5
1 PPM or less
Filter