14. Procedure to correct continuous rotation of the light.
14-1 Use the following tools
・Phillips head screw driver
・4mm Hexagonal wrench
14-2 Procedure
1) Turn off the power source
2) Remove the search light and place upside down on a suitable surface.
3)
Loosen and remove 8 screws as indicated in picture 49. Carefully lift the bottom cover off the base.
4) Remove all cables where connected to the printed circuit board.
Remove the bottom cover.
Picture 49
(Refer to picture 50)
Picture 50