Lamp Does Not Turn On - ACR Electronics RCL-600 Trouble Shooting And Parts Replacement Manual

For the remote controlled, xenon search light
Hide thumbs Also See for RCL-600:
Table of Contents

Advertisement

RCL-600
Remove the power head according to the directions on page 7. Turn on the
power by pushing the power button on the remote control panel. Check on
st
the 1
and 2
① If 24V DC is measured:
Check the Ballast, which is built into the power head, according
to directions on pages 8 and 9. "How to check the ballast".
The Starter is faulty.
Replace the starter according to
directions on pages 14 and 15.
② No 24V DC output?
There is a possibility of a problem inside the driver PCB.
Replace the printed circuit board PP-207A according to directions on page 10.
There is a possibility that the brush holder faulty.
Replace the brush holder according to directions on pages
Replace the printed circuit board PP-207A according to directions on page 21 and 22.
RCL-600 TROUBLE SHOOTING
TROUBLE SHOOTING

Lamp does not turn on

Replace the lamp according to the instructions
nd
contacts from the left side of PCB receptacle (see picture 3,
page 8) whether 24V DC is present.
Normal
"How to check the print circuit board PP-207A".
Normal
16, 17 and 18.
The printed circuit board PP-207A is faulty.
Does not turn on?
onononon the lamp
The Ballast is faulty.
Replace the ballast according to
directions on pages 11, 12 and 13.
3
Abnormal
Abnormal