To Check The Output (Lamp) Of Pcb Pp-207A; Lamp Does Not Turn On - ACR Electronics RCL-600 Trouble Shooting And Parts Replacement Manual

For the remote controlled, xenon search light
Hide thumbs Also See for RCL-600:
Table of Contents

Advertisement

3. Method to check PCB PP-207A
3-1 Use the following tools
・Hexagonal wrench of 4mm
・DC Multimeter.
3-2 Procedure
1) Remove the search light and place upside down.
2)
Loosen and remove 8 screws as indicated in picture 6.
3) Remove 2 cable connectors (P and N) as indicated inside circle in picture 7.
4)
Turn on the power source by pushing the power button on remote control panel. Measure on
terminals P (+) and N (-)with the DC Multimeter for 24V output. (Refer to picture 7)

(Lamp does not turn on)

Carefully lift the bottom cover off the base
Picture 6
Picture 7