11. OPTIONS AND AUXILIARY EQUIPMENT
(2) Connection example
ALM
RA1
NFB
(Note 4)
(Note 5)
Power
supply
RA2
Note 1. Terminals 13, 14 are normally open contact outputs. If the dynamic brake is seized, terminals 13, 14 will open.
Therefore, configure up an external sequence to prevent servo-on.
2. For the servo amplifiers from 11k to 22kW, be sure to connect P
When using the power factor DC reactor, refer to section 11.13.
3. Assign the dynamic brake interlock (DB) in the parameters No.PD07 to PD09.
4. Stepdown transformer is required for coil voltage of magnetic contactor more than 200V class in 400V class servo amplifiers.
5. Refer to section 1.3 for the power supply specification.
6. The power supply voltage of the inside magnet contactor for 400V class dynamic brake DBU-11K-4 and DBU-22K-4 is restricted
as follows. When using these dynamic brakes, use them within the range of the power supply.
Operation-ready
ON
EM1
OFF
MC
MC
SK
(Note 2)
Dynamic brake
DBU-11K-4
DBU-22K-4
Servo amplifier
U
V
W
MC
L
1
L
2
CN3
L
3
15
ALM
L
11
10
DICOM
L
21
P
DB
(Note 3)
P
1
5
DICOM
3
DOCOM
20
EM1
Plate
SD
(Note 6)
a
b
-P. (Factory-wired)
1
Power supply voltage
1-phase 380 to 463VAC 50Hz/60Hz
11 - 57
U
V
W
RA1
RA2
(Note 1)
14
13 U
V W
External dynamic brake
Servo motor
M