View Array Screen - HP Integrity BL870c User's & Service Manual

Blade
Hide thumbs Also See for Integrity BL870c:
Table of Contents

Advertisement

Pred Fail
Size(MB)

View Array Screen

The View Array screen enables you to view the current array configuration. To access the View
Array screen, press Enter on the View Existing Array field from the Select New Array Type screen.
You can perform the following actions on the View Array screen:
To view the next array, press N.
To create a new array, press C.
Following are descriptions for the View Array screen:
Array
Identifier
Type
Scan Order
Size (MB)
62
Installing the Server Blade Into the Enclosure
Missing
Disk is not responding.
Failed
Disk has failed.
Initializing
Disk is initializing.
CfgOffln
Disk is offline at host's request.
User Fail
Disk is marked failed at host's request.
Offline
Disk is offline for some other reason.
Inactive
Disk has been set to inactive.
Not Syncd
Data on disk is not synchronized with the rest of
the array.
Primary
Disk is the primary disk for a 2 disk mirror and is
OK.
Secondary
Disk is the secondary disk for a 2 disk mirror and
is OK.
Wrg Type
Device is not compatible for use as part of an IM
array.
Too Small
Disk is too small to mirror existing data.
Max Dsks
Maximum number of disks allowed for this type
of array has been reached or maximum number
of total IM disks on a controller has been reached.
No SMART
Disk doesn't support SMART and cannot be used
in a RAID array.
Wrg Intfc
Device interface (SAS) differs from existing IM
disks.
Indicates whether device SMART is predicting device failure (Yes, No).
Indicates the size of the device in megabytes (megabyte = 1024 x
1024 = 1,048,576 bytes). If the device is part of a two-disk array,
this field reflects the size of the array, not the size of the disks. If the
device is part of a three or more disk array, this field is the size of the
disk within the array.
When creating a striped array, the usable size of the array is
determined by the number of drives multiplied by the size of the smallest
drive in the array. In arrays consisting of different sized drives, excess
space on larger drives is unusable.
Displays the number of this array.
Displays the array identifier.
Displays the RAID type.
Displays the array scan order.
Displays the array size.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents