Water Supply And Drain Connections - Hoshizaki Serenity Series KMS-2000MLH Instruction Manual

Modular crescent cuber including condensing unit models srk-20h/3
Hide thumbs Also See for Serenity Series KMS-2000MLH:
Table of Contents

Advertisement

G. Water Supply and Drain Connections
See Fig. 17
Water supply and drain connections must be installed in accordance with applicable
national, state, and local regulations.
• Normal operating water temperature should be within 45°F to 90°F (7°C to
32°C). Operation of the icemaker, for extended periods, outside of this normal
temperature range may affect icemaker performance.
• To prevent damage to equipment, do not operate the icemaker when the water
supply is off, or if the pressure is below 10 PSIG. Do not run the icemaker until the
proper water pressure is reached.
• A plumbing permit and services of a licensed plumber may be required in some areas.
• External filters, strainers, or softeners may be required depending on water quality. Contact
your local Hoshizaki distributor for recommendations.
• Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If
the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.
• The icemaker and condensation drain line(s) and dispenser unit/storage bin drain line
must be run separately.
• Drain lines must have 1/4" fall per foot (2 cm per 1 m) on horizontal runs to get a good
flow. A vented tee connection is also required for proper flow.
• Drain lines should not be piped directly to the sewer system. An air gap of a minimum of
2 vertical inches (5 cm) should be between the end of the drain pipes from the icemaker,
condensation drain, and dispenser unit/storage bin and the floor drain.
WARNING
NOTICE
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Serenity seriesKms-2000mlhSrk-20h/3

Table of Contents